LT-0610P Intelligent Dimmer Rack

Main Functions:
6 dimmed outputs at 10A
One 10A MCB and one by pass switch for each channel
Applicable to distributed intelligent lighting control system
Compatible with LT-NET signal,DALI signal and DMX-512 signal
One group of 12V DC voltage output for control system
LED indications for three phase power supply,
and one LED for communication indication
128 preset scenes
128 divided zone
Fade time: 1~100s
Super thyristors and fast electromagnetic
switch reduce probability of thyristor burn-out by short-circuit
Each channel is provided with one professional grade filter(100us)
for efficient attenuation of lamp filamout noise
Automatic voltage limiting function keeps voltage output
within 230V to extend service life of lamps
Applicable to control of incandescent lamps, tungsten halogen lamps, and transformer-fed low voltage lamps


Product Characteristics
Control electronics: full digital, microprocessor controlled;
Ratings: dimmers rated for continuous duty: 6 x 2 kW;
Max. duty of LT-0610P 12 kW;
Operating environment: 0℃ to 40℃; relative humidity max. 90% at 25℃;
atmospheric pressure < 106kP.
Power supply system: 3NPE 400V 50Hz
(TN-S system, neutral directly connected to earth, 230V between phase and neutral);
Reduced-size N linear diameter is not allowed;
Single-phase operation is possible;
Supply voltage range: 230 V±10 %;
Rated supply current: Star system 3-phase 3N with PE supply:
20A per phase at 230V;Single-phase supply: 60A at 230V;
Dimmer protection: MCB mini breaker (Max. breaking capacity 6000A);
Control signal inputs: DMX and LT-NET(DALI)
signal can be switched over by nternal position selector switch;
DMX signal:correct DMX signal is continuous flash;
LT-NET(DALI) signal:correct LT-NET signal is red and green alternately;
DC supply for panels:12V/0.2A;
Front panel indicators: power is OK or not for each channel (MCB trip);
DMX512 or LT-NET control signal is OK or not (LED indication for communication);
Power supply failure (LED indication for power supply);
Dimmer test functions: When emergency button is pressed, internal trimmer potentiometer can be applied to dimming within 0 to 100% range for 6 channels;
By pass switch:
when the dimmer function module go wrong,take the by pass switch on

Response time: DMX≤30ms;
Dimmer resolution: 1024 steps;
Power semiconductors:antiparallel thyristors,Min. load per dimmer ≥60W
DC component in output voltage:below 1V in rated load range;
Types of load:suitable for incandescent lamps, tungsten halogen lamps,
and transformer-led low voltage lamps;
Electromagnetic compatibility standard: EN55103-1: 1996;
EN55103-2:1996;
Safety standard: EN60439 ,EN60950
Ingress Protection: IP2X


Protection:
Protection for each channel by MCB (breaking capacity 6kA )
to ensure safe operation of system under rated conditions;
Power supply ingoing line diameter: 25mm2 for rigid wire, 16mm2 for stranded wire;
Load terminal outgoing line diameter: 6mm2 for rigid wire, 4mm2 for stranded wire;
Cables enter from the knockout cable hole at the top of the enclosure,
or from the cable entry in the rear plate;
The terminal of control signal lines enter from the cable hole at the bottom.


Communication:
DMX512/1990 communication protocol;
LT-NET (DALI)interface protocol.


Cooling: